ULTRA SMALL HIGH SPEED and HIGH SENSITIVITY THRESHOLD DETECTOR

THA1840
Specifications
Frequency Range 18 – 40 GHz

To meet the following Environmental Conditions:

Operating Temp.:   -40 to +85°C

Storage Temp.:      -54 to +105°C

Mechanical Shock:
Per MIL-STD-810F, Method 516.5

Vibration:
Per MIL-STD-810F, Method 514.5

Humidity:
Per MIL-STD-810F, Method 507.4

Material: SS303

Finish:     Gold Plating per MIL-G-45204B

Power Supply:
+12 to +15V @ 120 mA max
– 12 to -15V at 50 mA max

Dynamic Range
Threshold Setting
Pulsed Signal
-35 to -20 dBm
-31 to +10 dBm
Flatness ±1.5 dB max.
Propagation Delay 15 nsec. max.
Output TTL compatible
Pulse Stretching 200 nsec. max
VSWR 2.5:1 typ
Threshold Uncertainty ±0.75 dB max
Threshold Setting 0 to 4 volts
  1. Pulsed signal should be at least 4dB above the threshold setting.
  2. Pulse response is 30 nsec. pulse with to CW.
  3. Max Input Power without damage is +15 dBm.
  4. Voltage Control Pin (V.C.) sets the threshold setting and can be set externally by the user. The unit is preset to minimum level internally. It is not necessary to use the pin (V.C) unless the threshold setting needs to be higher than specified min. level.
  5. To set the threshold setting to a higher level also improves response time.
Scroll to Top