Super High-Sensitivity Threshold DetectorTHAS0540L-2
| Features: | • | Very Low Power |
| • | Operates from single 5V DC Supply | |
| • | Super Fast Response | |
| • | Very Wide Dynamic Range |
| Applications: | • | Lab work or Off Air Signal Detection |
| • | High Speed Data Processing | |
| • | Battery Operated Devices requiring small size and low power |
SPECIFICATIONS |
|
| Frequency Range | 0.25 to 0.75 GHz |
| Dynamic Range Setting
Signal |
-40 to -25 dBm
-36 to +10 dBm |
| Flatness | ±0.6 dB max |
| DC Supply +5 ±0.5V (excluding load) | @ 60 mA max (180 mw) |
| Max Input Level | +18 dBm |
|
Environmental Conditions:
Operating Temperature: -40 to +85°C Storage Temperature: -40 to +100°C
Material: SS303 Finish: Gold Plating
|
Pulse Response: 50 nsec P.W. to CW |
| Propagation Delay: 15 nsec max | |
| Pulse Stretching: 100 nsec max | |
| Output : TTL, Drives 50 ohm load | |
| Threshold Uncertainty: ±0.5 dB max | |
| * Threshold Setting: 0 to 2 V | |
| VSWR: 2.5:1 max | |
| * Threshold Setting is set internally to minimum. No need to use it unless there is excessive front end noise or you need less Pulse stretching @ the cost of slightly lower sensitivity. | |
| These units offer DC Reverse Voltage Protection | |