Ultra-Small Pseudo AC Coupled Detector Log Amplifier (ERDLA)

ERDLA02602-1-C
Specifications
Frequency Range 2 to 6 GHz

Designed to meet the following Environmental Conditions:

Operating Case Temperature: -40 to +85°C

Extended Operating Range: -50 to +95°C

Storage Temperature:               -54 to +100°C

Mechanical Shock:    Per MIL-STD-202, Method 213, Cond J

Vibration:                    Per MIL-STD-202, Method 214, Cond A

Humidity:                  Per MIL-STD-81 OF, Method 507.4

Mechanical:                All SMA connectors are field replaceable

Material:                      SS303

Finish: Nickel Plating per MIL-C-26074E

CW Immunity Range: TSS to -15dBm
CW Baseline Shift: 50mV max
CW Immunity Settling Time: 1 Oms max
Droop: 2.0dB max (> -60 dBm)
Matching 2.4 dB max

 Dynamic Range -68 to +5 dBm
TSS -71 dBm max
Input VSWR 2.0:1 max
Rise Time 10 nsec typ 20 nsec max
Recovery Time 350 nsec max
Settling Time 40 nsec max
Pulse Response (Positive) 50 nsec to 100 μsec
Log Accuracy ±1.5dB max (±2.0dB w.temp)
Log Slope (into 100 ohm load) 50 ±4 mV/dB
Power Supply

Operates ±12V to ±15V

+9V to +12V @ 180 mA max

– 12 V at 90  mA max

DC Offset 0 ±50 mV
Noise Level 100 mv PP max
Maximum Input Level  +20 dBm
Flatness (@ -50 & -10dBm) ±1.5dB max
Scroll to Top