SPECIFICATIONS |
||||
Frequency Range |
2 to 18 GHz |
Environmental Requirement
• Operating Temperature: -28 to +85⁰C
• Storage Temperature: -40 to 85⁰C Per: RTCA/DO-160C,Sec.4
•Temperature Shock: 5⁰C/min Per: RTCA/DO-160C,Sec.5
• Humidity: 95% Condensing Per: RTCA/DO-160C, Sec.6
• Fungus: Per:MIL-STD810E,Met.508
• Mechanical Shock: 40gs Per: MIL-STD-810E,Met.51 6.4
• Vibration: Per: RTCA/DO-160C,Sec.8
• Altitude: Operating: 0 to 25,000ft Non-Operating: 0 to 40,000ft Per: RTCA/DO-160C,Sec.4
• EMI: Field Strength IV/Meter over 30 Mhz to 18 GHz. Per RTCA/DO-160⁰C,sec.20 |
||
Dynamic Range |
-40 to +20 dBm |
|||
TSS |
-42 dBm min |
|||
Input VSWR |
2.5:1 max |
|||
Rise Time |
20 nsec. max |
|||
Recovery Time ( @ +15 dBm) |
500 nsec max |
|||
Settling Time ( From 90% RT ) |
to ± 0.5 dB SS, 25 nsec |
|||
Pulse Response | 50 nsec to 250 μsec | |||
-40 -0 dBm
Log Linearity -40 to +20 dBm |
± 0.5 dB max
± 1.0 dBm |
|||
Log Slope (into 93 ohm load) | 75 ± 2 mV/dB, 66 ft RG71B | |||
Power Supply | + 12 to +15 V at 150mA max
– 12 to -15 V at 150 mA max |
|||
Video Out @ -40dB |
300 ± 50 mV | |||
Baseline Noise | 100 mV RMS max | |||
Flatness (video) @ – 20 dBm | ±1.0 dB max ( ± 75 mv) | |||
DC Offset | 0 ± 75 mV max | |||
CW Immunity Range:
CW Attack time: CW Release time: Pulse Droop |
TSS to -10 dBm
1.5 msec. max 0.25 msec. max 1 dB to 250 µsec PW |
|||
Duty Cycle |
0 to 70% ( DC= PW+500hs |