SPECIFICATIONS
Frequency Range 8.0 to 12.0 GHz
Dynamic Range -35 to +10 dBm
Flatness  ± 0.5 dB max
VSWR @ -20 dBm or lower

@ above -20 dBm

2.2:1 max

2.8:1 max

Rise Time 15 nsec typ, 20 nsec max
Recovery Time at 0 dBm 500 nsec typ
Log Accuracy From -35 to +10 dBm ± 0.6 dB typ, ± 0.8 dB max
Output Voltage @ Input of -35 dBm 200 ± 50 mV
Log Slope 40 ± 3  mV/dB
Power Supply ( excluding  external load) ± 12 volts at 60  mA max
Operating Case Temperature Range -20°C to +70°C
Output Load Impedance 125 Ohms
TSS -40 dBm
Signal Capability 40 nsec to CW