SUCCESSIVE DETECTION LOG AMPLIFIER (SDLAC) CW IMMUNESDLAC112802A-C
|
|
Specifications | ||
---|---|---|
Frequency Range | 1 – 18 GHz | Designed to meet the following Environmental Conditions:
Operating Case Temp.: -40 to +85°C Vibration: Humidity: Mechanical: SMA Connectors |
Dynamic Range | -68 to 5 dBm | |
TSS | -70 dBm max. | |
Input VSWR | 2.5:1 max. | |
Rise Time | 9 nsec. typ., 12 nsec.max. | |
Fall Time | 12 nsec. typ., 20 nsec.max. | |
Recovery Time | 80 nsec. max. | |
Propagation Delay | 15 nsec. max. | |
Log Accuracy | ±1.5 dB max. (±2.0 dB w. temp) | |
Video Output Drift over temp and dynamic range | -0.04 dB/°C nom | |
Log Slope (into 100 ohm load) |
50 ± 5 mV/dB (1) | |
Power Supply Operates ±12V to ±15V | +12V at 350 mA max. -12V at 100 mA max. |
CW Immunity Range: TSS to -25 dBm Pulse Response: 25 nsec. to 50 µsec. (3) CW Baseline Shift: 100 mv max Droop: 1.0 dB max.(from -65 to -25 dBm) CW Attack Time: 500 µsec. typ. |
DC Offset | +100 ±50 mV (2) | |
Maximum Input Level | +20 dBm | |
Flatness | ±2 dB max. (or ±100 mV) | |
Baseline Noise | 20mv RMS |
This product offers the following options: |
---|
(1) Slope; 25 mV/dB to 75 mV/dB |
(2) DC offset; -100 to +400 mV. |
(3) Pulse Response to 300 µsec. or an option |
Note: | Above specifications are based on a slope of 50mV/dB.Some parameters may change for other slope requirements. |
---|